(b) Remove the top and filter element from filter assembly.
Do not use gasoline, kerosene, or other low flashpoint solvents. A
serious explosion may result.
(c) Wash filter element with approved solvent or detergent and water
solution.
(d) Dry filter element thoroughly.
(e) Apply fresh oil by spray or dip and let excess oil drain. Use oil
type suggested by manufacturer.
(f) Clean filter body.
(g) Reinstall filter element and top to filter assembly.
(h) Remove tag from controls.
3.3 Oil-Bath Filter. Clean the filter assembly as follows:
(a) Shut down compressor and tag controls.
(b) Remove filter assembly from compressor.
Do not use gasoline, kerosene, or other low flashpoint solvents. A
serious explosion may result.
(c) Wash filter element with approved solvent or detergent and water
solution.
(d) Dry filter element thoroughly.
(e) Clean and dry filter oil sump.
(f) Add oil to oil sump to indicated level.
(g) Reinstall filter element and top on filter assembly.
(h) Reinstall filter assembly on compressor.
(i) Remove tag from controls.
4-3