ROOFING
Asphalt strip shingled roof-Continued
n Shingles:
Clawed edges
Absence of minerals
Missing tabs/shingles
Breaking
Weather damage
n
Penetrations:
Deterioration of the surrounding flashing
8.2.2 Built-up roof: Check for:
n Gravel Stops:
Missing stops
Loose stops
Rust
Evidence of numerous repairs
Problems at the creased corner which forms a 90 degree angle
n Flashings:
Metal
Check the valley, step, and cap flashings for
Missing sections
Rust
Punctures
Wind damage
Check the cap and step flashings for
Proper reglet seals
Separation from vertical surfaces