MATERIAL CONTROL AND PROVISIONING
CHAPTER 5
5.1 MATERIAL PROVISIONING REQUIREMENTS
Stocking Levels.
An important part of the safe
5.1.1
operation and maintenance of a manned hyperbaric facility is having
adequate  levels  of  spare  parts  and  consumables  in  stock.
Previously, in Chapter 3, requirements and guidance concerning the
provisioning of spare parts and consumables was addressed, with
emphasis on the availability of spare parts for failure management.
This section will provide additional guidance with respect to the
provisioning of maintenance materials for hyperbaric facilities.
The following minimum provisioning requirements are necessary
to  conduct  safe  hyperbaric  and  diving  operations. Facility
managers and other responsible personnel should verify compliance
with these requirements on a regular basis.
Consumables.
Sufficient consumables shall be available
(e.g., filter elements, CO2 absorbent, lubricants, etc.) to operate
the  facility  for  twice  the  duration of  the  maximum  operating
Prior  to  conducting  operations  consumables  will  be
profile.
checked to verify availability and, where applicable, expiration
dates.
b.
Mandatory Spare Parts and Repair Kits.
For all HAZCAT
II  systems,  components,  and  equipments  (Chapter  3,  Section  3
refers) required spare parts and software repair kits shall be
available at the facility and ready for immediate installation to
This  includes  one  (1)  twenty  foot
conduct  mandatory  repairs.
length of every size piping installed in the system.
Gas Supplies.  Available gas supplies (e.g., compressors,
c.
storage  flasks)  shall  be  capable  of  meeting  the  pressure  and
duration requirements of the U.S. Navy Diving Manual.  For systems
not addressed by the U.S. Navy Diving Manual the minimum required
gas supply shall be established by the NAVFAC SCA.
To assist commands in establishing provisioning requirements
for components, software repair kits and consumables, Figure 5-1,
NAVFAC  Recommended  Provisioning  Decision  Tree  for  Hyperbaric
Commands shall develop and maintain a
Facilities,  is provided.
list  of  provisioning  items required  to  support  the  hyperbaric
facility.  As a minimum this provisioning list shall contain the
following:
5-1