Custom Search
 
  
 


Concurrent Technologies Corporation
Remediation Survey
Ground Water Pump and Treat with an Air Stripper
Page 6
3.
Design Tools:
4.
Remediation Hardware:
5.
Capital Cost:
6.
Operating and Maintenance Cost:
V.
TECHNOLOGY PERFORMANCE
A.
Remediation Technology Choice
1.
Other Remediation Technologies Considered for this Site:
2.
Why was Ground Water Pump and Treat with an Air Stripper Chosen over Other
Technologies?
Although more expensive than air stripping, the UV/Peroxide system was selected because
it destroys contaminants rather than transferring contaminants to other media.
Remediation Technologies used at this Site in addition to Ground Water Pump and Treat
3.
with an Air Stripper:
Advanced oxidation processes (AOPs)
B.
Operation of Ground Water Pump and Treat with an Air Stripper
1.
Duration:
5/88 - 2/94 +
2.
Other:
C.
Lessons Learned
1.
Lessons Learned about the Operation of the Equipment:
The ability to control flows from the central treatment systems building would be less difficult than
manually adjusting individual well heads.
Predicting aquifer restoration is complicated due to hydrogeologic variablity.