Quantcast Technology Design - nav20071

Custom Search
 
  
 


Concurrent Technologies Corporation
Remediation Survey
Ground Water Pump and Treat with an Air Stripper
Page 4
IV.
TECHNOLOGY DESIGN
Typical System Components:
Extraction Wells (Section A)
Oil Water Separator (Section B)
Air Stripper (Section C)
Carbon Treatment (Section D)
Other
A.
Extraction Wells
1.
Design Goals
Provide 100 GPM to treatment system
a.
2.
Design Parameters
a.
Pipe Type:
Steel
b.
Pipe Diameter:
8"
c.
Depth:
185 ft.
d.
Screen Interval  screen-depth to bottom 170 ft; diameter-4":
e.
Screen Type:
f.
Number and Spacing:
g.
Other:  Concrete grout; grout bottom-10 ft below surface
3.
Design Tools:
4.
Remediation Hardware:
5.
Capital Cost:
6.
Operating and Maintenance Cost:
B.
Oil and Water Separator - Not applicable.
1.
Design Goals:
2.
Design Parameters
a.
Flow Rate:
b.
Efficiency:
c.
Other:





 