MIL-HDBK-1013/1A
1)
Low-Severity Threat.
There are no low-severity threat vault
doors.
2)
Medium-Severity Threat. Vault doors for the medium-severity
threat are GSA Class 5 vault doors (see Figure 29) that are designed to
comply with Federal Specification AA-D-00600C. They provide a forced-entry
penetration delay time of 10 minutes.
3)
High-Severity Threat. Vault doors for the high-severity
threat are GSA Class 8 vault doors that are designed to comply with Federal
Specification AA-D-2757. They provide a forced-entry penetration delay time
of 15 minutes.
5.5.5.4
Magazine Doors. Table 31 identifies design data for high-severity
threat level AA&E storage facilities. Table 32 identifies magazine door
design data for the very high-security threat level.
Table 31
High-Security Magazine Door
+)))))))))))))0)))))))))))))))))))))))0))))))))))))))))))),
*
Element *
* Penetration Time *
Construction
*
*
*
*
(minutes)
/)))))))))))))3)))))))))))))))))))))))3)))))))))))))))))))1
* Panel
*
*
*
See Table 16
4
*
*
*
*
* Lock/Hasp *
*
*
Figures 40 and 41
<1
*
*
*
*
.)))))))))))))2)))))))))))))))))))))))2)))))))))))))))))))-
Table 32
Very High-Security Magazine Construction
+))))))))))))))))0))))))))))))))))))))))0))))))))))))))))),
* Element
* Construction (a)
* Penetration Time*
*
*
*
(minutes) (b) *
/))))))))))))))))3))))))))))))))))))))))3)))))))))))))))))1
* Panel
*
*
*
Figure 42
20
/))))))))))))))))3))))))))))))))))))))))3)))))))))))))))))1
* Locking System * High-Security
*
*
20
*
* Internal-Locking
*
*
*
* System
*
*
.))))))))))))))))2))))))))))))))))))))))2)))))))))))))))))-
(a)
Contact the Naval Civil Engineering Laboratory for
details.
(b)
Penetration time is for hand/power/and thermal tools.
Also defeats explosive charges.
146