MIL-HDBK-1013/1A
Table 40
Stud-Girt Construction Retrofit Options For Medium Threat Levels
+))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))0)))))))))))))),
*
*  Penetration *
*
*
*
Time
*
*
(minutes)  *
Construction
/))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))3))))))))))))))1
*
*
*1.  2- by 4-inch (50- by 100-mm) wood stud frame at 16
*
*
*
inches (400 mm) on-center w/bevel siding at 1.5-inch
*
*
*
(37.5-mm) lap joints, 1-layer No. 15 felt paper, and
*
*
*
1- by 6-inch (25- by 150-mm) sheathing diagonally and
*
*
*
3/8-inch (9.4-mm) gypsum wallboard.  Attach to
*
*
*
interior:
*
*
*
*
*
*
o  3/4-inch (19-mm) plywood, No. 9 expanded metal and
*
3/4-inch (19-mm) plywood, all attached to interior.  *
*
5.0
/))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))3))))))))))))))1
*
*
*
*2.  1-inch (25-mm) tongue-and-groove on 1/2-inch (12.5-mm)  *
*
*
*
*
plywood.
/))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))3))))))))))))))1
*Attach to interior:
*
*
*
*
*
*
*
*
o  9-gauge (3.8-mm) metal fence, nailed.
1.8
*
*
*
o  3/16-inch (4.7-mm) steel plate.
1.9
.))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))2))))))))))))))-
mm) on-center each way up to 6 inches (150 mm) thick with No. 4 (12.7-mm-
diameter) rebar at 12 inches (300 mm) on-center.
Composite slab/beam systems range from 6 inches (150 mm) thick with
No. 5 (15.9-mm-diameter) rebar at 12 inches (300 mm) on-center each way up to
12 inches (300 mm) thick with No. 5 (15.9-mm-diameter) rebar at 6 inches (150
mm) on-center.
Composite metal deck and slab systems range from 1-1/2-inch (38-mm)
thick, 22-gauge (0.8-mm) corrugated steel decking with 2-1/2-inch (63-mm)
concrete topping poured with 6- by 6-inch W 1.4 x W 1.4 wire mesh [total 4
inches (100 mm)] up to 3-1/2-inch (90-mm) thick, 22-gauge (0.8-mm) steel
decking with 4-1/2-inch (115-mm) concrete topping poured with 6- by 6-inch W
1.4 x W 1.4 wire mesh [total 8 inches (200 mm)].
ii)  Conventional systems which are cast-in-place as structural
members.  One- and two-way slab systems range from 6 inches (150 mm) thick
with (minimum) No. 4 (2.7-mm-diameter) rebar at 12 inches (300 mm) on-center
up to 18 inches (450 mm) thick with (maximum) No. 5 (15.9-mm) rebar at 3
inches (75 mm) on-center.
The penetration resistance of waffle slab systems should be
evaluated on the basis of slab thickness between the reinforcing ribs.