PLANS, SPECIFICATIONS AND COST ESTIMATE
REVIEW REQUIREMENTS
REVIEWERS
INITIALS AT:
ARCHITECTURAL
100%
35%
All column and wall locations
1.
agree with structural drawings.........
2.
Site plans clearly indicate existing
conditions and new work.................
Elevations and sections agree with
3.
plan views , including roof lines,
window and door openings........,.......
4.
Masonry openings for windows and
doors shown . . . . . . . . . . . . . . . . . .
Where new, smaller windows are installed
5.
in existing masonry openings, space
outside windows are filled with mortar..
All window and door installation details
6.
are  clearly  indicated...................
Expansion joints are used...............
7.
8.
Verify partial floor plans against small
scale floor plans . . . . . . . . . . . . . . . .
9.
Verify reflected ceiling plan against
architectural floor plan to ensure no
variance with rooms . . . . . . . . . . . . . . .
Check light fixture layout against
10.
electrical, check ceiling
deffusers/registers  against  mechanical,
check all soffits and locations of vents
Partial floor plans agree with small
11.
scale floor plans . . . . . . . . . . . . .
Show all trees, shrubs and outline of
12.
brush and status, i.e. new8 relocated, or
existing remain in place or removals...
13.
Fire resistive wall, floor and ceiling
materials shown on interior elevations
agree with finish schedule for each
room....................................