Custom Search
|
|
|
||
April 1997
d.Interior Elevations/Sections showing:
physical security features.
9)
1) Toilets with fixtures, vanities, partitions,
Toilet partition, shower pan, floor/roof/
balcony drains, and waterproofing
finishes, and accessories with labels and
details.
reference symbols.
10)
2) Typical dormitory room with lighting,
Expansion joints, crack control joints for
stucco/brick/cmu/concrete/ceramic
wall HVAC registers and returns, built-
tile/plaster, and joints between different
in furnishings, doors, windows, and
finish materials.
outline of equipment (such as
11)
Stair/balcony railings and mounting
refrigerators) and furniture (such as
brackets,
wall-mounted
doorstop
beds, wardrobes, etc.) which are "not-
bracing, vanity bracing, locker/
in-contract". This is necessary for
weapons rack mounts, curtain wall/
coordination and conflict prevention.
3) Kitchen/food preparation area with
large window protective railings, and
partition corner/corridor wall bumpers.
equipment outlined, electrical outlets
12)
Signage construction and method of
and switches at proper heights, fire
mounting.
extinguishers, alarm bells/horns, and
13)
HVAC equipment and registers/
Necessary notes.
14)
returns.
Titles referenced by Reference Symbol
4) Janitor closets with shelving, wall
convention to Plans, Elevations, and
hooks, and built-in equipment.
Building Sections.
5) Stairs with dimensioned railings, treads,
f.
Schedules showing:
risers, nosings, and framing.
1) Doors and frames with fire and
e. Wall Sections, Sections, and Details
acoustical rating, physical security
showing:
feature notes, and detail reference
1) All sections and details (including
numbers.
2) Windows with frame material, glazing
flashing, drip moldings, weepholes,
vents, etc.) necessary for construction.
type, fire and acoustical rating, physical
2) Sections at minimum scale of 3/4"= 1'-
security feature notes, and detail
0".
reference numbers.
3) Isometric details for each roof flashing
3) Louvers with frame, vane operation, fire
condition at minimum scale of 3"= 1'-0"
rating, physical security feature notes,
and with all applicable notes.
and detail reference numbers.
4) Interior finish materials for floor, base,
4) Isometric detail of scuppers showing all
walls, wainscot and ceiling with
flanges.
5) Joint covers for metal coping covers and
ceiling height. Also include
gravel stops.
6) Roof crickets.
7) Wall and roof insulation with "R-
8) Door and window frame "head, jamb,
and sill" details.
Also astragals,
weatherstripping, thresholds, floor level
changes (such as at entrances), and
ARCHITECTURAL SUBMITTAL REQUIREMENTS
13-7
|
||