Custom Search
|
|
|
||
STRUCTURAL
Waterfront-Topside-Continued
Proper net tension
End fittings - Check for
Proper operation
Corrosion
Cracking or separation of fender shell around end fit-
tings
Underside -
n Elastomer shell - Note the size and location of the damage on a sketch.
Check for
Cuts
Tears
Punctures
n Concrete:
Pile caps - Check for
Damage
Broken or missing members
Cracks
Spalling
Rust
Exposed steel reinforcement
Bearing, batter, and fender piles - Check for
Damage
Broken or missing members
Cracks
Spalling
Rust
Exposed steel reinforcement
5-51
|
||