Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 


a.  HAZCAT I items include the pressure boundary surrounding
the occupants/divers up to the first pressure piping stop valves.
HAZCAT I items, dependent upon the design, may also include other
system  piping  and  components.
For example,  if  no  completely
independent stand-by system exists then all piping and components
would be HAZCAT I.
Pressure vessel (of occupants/divers).
o
Pressure vessel viewports.
o
Pressure vessel penetrator fittings.
o
A n y  other  item  or  component  which  meets  the
o
definition for HAZCAT I in paragraph 2.6.3.
HAZCAT  II  items  include  the  systems,  equipments  and
b.
components which provide life support to the occupants/divers and
for which a completely independent standby system exists.
Primary Air Systems
o
Stand-by Air Systems
o
Vent Systems
o
BIBS Systems
AIR, OVERBOARD DUMP)
o
Electrical Lighting
o
o
A n y  other  item  or  component  which  meets  the
o
definition of HAZCAT II in paragraph 2.6.3.
HAZCAT  III  items  include  the  systems,  equipments  and
C.
components providing support to the occupants/divers, which are
not life critical, but for which action is required to continue
the dive.
Monitoring Systems
o
Flood and Drain Systems for Wet Complexes
o
Any other component which meets the definition of
o
HAZCAT III in paragraph 2.6.3.
HAZCAT  IV  items  include  all  systems,  equipments  and
d.
components which are not HAZCAT I, II and III, and for which
repairs can be made at a convenient time.
Medical
and  vent
System
o
(excluding lock pressure boundaries)
Chamber Sanitary Flushing System
o
2.7
REPORTING
REQUIREMENTS
2.7.1
SCA Reports.  The following are excerpts from SS521-
AA-MAN-010 addressing required reports to the System Certification
Authority (SCA):
a.  Operating Limits.  The diving system shall operate within
the  certified  operational  limits  specified  as  part  of  the
Operation outside of
requirements for sustaining certification.
the authorized operational limits without a valid waiver will
result in termination or suspension of system certification.  Any
2-8








Western Governors University
 


Privacy Statement - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business