Custom Search
|
|
|
||
FLEXIBLE HOSE INSPECTION REPORT (ATTACHMENT)
INSPECTION REQUIREMENTS (DEFECTS)
ALL FLEXIBLE HOSE ASSEMBLIES SHALL BE INSPECTED FOR THE FOLLOWING
DEFECTS:
1.
EVIDENCE OF LEAKAGE AT FITTING ENDS.
DISCOLORATION OF FITTINGS. (THIS COULD INDICATE POSSIBLE
2.
RUSTING OF WIRE REINFORCEMENT OF HOSE)
3.
SLIPPAGE OF HOSE OUT OF FITTING.
4.
SEALER NOT VISIBLE.
5.
CRACKING OF OUTER RUBBER COVER.
6.
SOFT SPOTS OR BULGES ON HOSE BODY.
7.
RUBBER COVER RUBBED THIN BY CHAFING OR ABRASION.
8.
DAMAGED FITTING.
9.
LARGE AREA OF HOSE COVERED WITH PAINT.
10.
STEEL SEGMENTED SOCKETS IN SEA WATER SYSTEMS.
11.
FITTED FITTINGS, OR LOOSE OR SHIFTED BANDS OR RETAINING
RINGS.
12.
MIS-BATCHED HOSE AND FITTINGS.
13.
HANGERS BROKEN, DISTORTED OR DAMAGED.
14.
ADDITIONAL HANGERS REQUIRED.
15.
TWISTED OR DEFLECTED.
16.
IMPROPER CLEARANCE.
17.
IMPROPER BEND RADIUS.
18.
FREE LENGTH OF HOSE NOT CORRECT.
19.
NO DATE OF HOSE MANUFACTURE.
20.
NO INSTALLATION DATE. (METAL TAG)
21.
NO HOSE IDENTIFICATION.
22.
HOSE HAS EXCEEDED SERVICE LIFE. REPLACE.
23.
IMPROPER HOSE INSTALLED.
E-8
|
||