Custom Search
 
  
 


In  accordance  with  the  "CONSEQUENCES  OF  THE  CONTRACTOR'S
FAILURE TO PERFORM REQUIRED WORK" clause FAC 5252.246-9303, deductions
may be taken for nonperformed or unsatisfactory work.  In the event, the
price of nonperformed or unsatisfactory work cannot be determined from
the prices set out in the Schedule, or on the basis of the actual cost
to  the  Government,  estimated  methods  may  be  used.
Engineered
Performance Standards (EPS) or other estimating sources may be utilized
to estimate the cost of nonperformed work or the costs which would be
incurred in remedying unsatisfactory work.  The Government may estimate
the cost using wage rate and fringe benefits included in the wage
determinations included in the contract.
Government estimates of the
Contractor's overhead and profit rates, and Government estimates of
material costs if applicable.
Liquidated damages, to compensate the
Government for administrative costs and other expenses resulting from
the nonperformance or unsatisfactory performance, will be calculated in
accordance with the "CONSEQUENCES OF CONTRACTOR'S FAILURE TO PERFORM
REQUIRED WORK" clause.
A list of Engineered Performance Standards is
contained in Attachment J- [fill in blank] .
E.8
CONTRACTOR QUALITY CONTROL (QC).
************************************************************************
NOTE:  If the contract is to be awarded on the basis of a Request for
Proposal (RFP) which includes the evaluation of a technical proposal,
delete subparagraph (1) and substitute subparagraph (1)(optional).
************************************************************************
(1)
The Contractor shall establish and maintain a Quality Control
Program in accordance with the FAR 52.246-4, "INSPECTION OF SERVICES -
FIXED PRICE" clause, Section E, to ensure that the work performed under
the contract conforms to the contract requirements.
The Contractor
shall submit to the Contracting Officer, a Quality Control Plan (QCP)
for approval 15 calendar days after award of the contract.  A general
description of the Contractor's Quality Control (QC) program shall be
available for Government review during the preaward survey.
(1) (optional). The Contractor shall establish and maintain a Quality
Control Program in accordance with the FAR 52.246-4, "INSPECTION OF
SERVICES - FIXED PRICE" clause, Section E, to ensure that the work
performed under the contract conforms to the contract requirements.  The
Contractor shall submit to the Contracting Officer, a Quality Control
Plan (QCP) as part of the Technical Proposal.
(2)  The Contractor's QCP shall provide top Contractor management with
an effective and efficient means of identifying and correcting problems
throughout the entire scope of operations.
(3)
The QCP shall include: