Quantcast Figure 31. Site-Built Sentry Booth/Gatehouse Floor Plan

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 


MIL-HDBK-1013/10
Figure 31.
Site-Built Sentry Booth/Gatehouse Floor Plan.
Windows.  Windows selected for sentry booths and gatehouses should
4.3.2.2
be placed at a continuous minimum height (normally 36 inches (914.4 mm) above
the floor) at all elevations to maximize surveillance capability.  Other
options to consider are:
Smoked or tinted glass.
a)
One way viewing.
b)
Ballistic-resistant
glazing.
c)
When designing or selecting ballistic-resistant glazing, be
certain that the wall construction and adjacent products maintain the same
level of protection.  See MIL-HDBK-1013/1 for ballistic-resistance design
information.
Floors.  Floors will be constructed of reinforced concrete with
4.3.2.3
the surface 6 inches (154.4 mm) or more above grade or adjacent walkways.
Construction.  Based on the local area threat analysis and the
4.3.2.4
level of protection required, the criteria contained in MIL-HDBK-1013/1 will