MIL-HDBK-1013/12
4.6.1
Required Information. The following information is
required for the evaluation attack analyses procedure:
a)
Project identification
b)
Asset identification
c)
Number of stacked plates in cross-section
d)
For each stacked plate:
1) Type of glazing material
2) Thickness of plate
3) Number of layers in plate
4) For each layer in a glass plate:
i) Layer thickness
e)
Cross-section type
f)
Frame thickness
g)
Removable stop thickness
h)
Bite depth
i)
Rabbet depth
j)
Anchor bolt type
k)
Anchor bolt diameter
l)
Anchor bolt embedment
m)
Material types and thicknesses in wall cross-section
n)
Design Basis Threat. This information is determined
using Appendix D and is recorded on the Glazing
System Design Criteria Summary worksheet.
o)
Worksheets (see Appendix B):
1) Cross-Section Evaluation (CSE)
2) Frame Evaluation (FE)
3) Anchorage Evaluation (AE)
4) Wall Evaluation (WE)
4.7
Selection Reconciliation Procedure. This procedure
provides structures to reconcile differences in glazing system
component minimum requirements against ballistic, bomb, and
forced entry attacks. Figure 10 shows the process chart for the
analysis reconciliation procedure. Figure 11 explains the
structures presented in Figure 10.
39
|
||