<1> Select Using Threat Severity Level. Select a process structure on the basis of
threat severity level.  For a threat severity level of low, proceed to <2>.  For
a threat severity level of medium, proceed to <3>.  For a threat severity level
of high, proceed to <4>.  For a threat severity level of very high, proceed to
<5>.
<2> Get Cross-Section to Protect Against Low Severity Level. elect one or more cross-
S
sections from Table 8.  Enter the cross-section thicknesses in their appropriate
rows of column (d) on the Cross-Section Selection worksheet (see AppendBxfor
i
all worksheets).  Proceed to <6>.
<3> Get Cross-Section to Protect Against Medium Severity Level. elect one or more
S
cross-sections from Table 9.  Enter the cross-section thicknesses in their
appropriate rows of column (d) on the Cross-Section Selection worksheet.
Proceed to <6>.
<4> Get Cross-Section to Protect Against High Severity Level. elect one or more
S
cross-sections from Table 10.  Enter the cross-section thicknesses in their
appropriate rows of column (d) on the Cross-Section Selection worksheet.
Proceed to <6>.
<5> Get Cross-Section to Protect Against Very High Severity Level. et one or more
G
cross-sections from Table 11.  Enter the cross-section thicknesses in their
appropriate rows of column (d) on the Cross-Section Selection worksheet.
Proceed to <6>.
<6> Get Ballistic Resistant Frame Thicknesses.Get frame thicknesses fromTable 6.
Enter the frame thicknesses in their appropriate rows of column (d) on the Frame
Selection worksheet.  Proceed to <8>.
<7> Get Ballistic Resistant Wall Thickness. Get one or more wall thicknesses from
Table 7.  Enter wall thicknesses in their appropriate rows of column (d) on the
Wall Selection worksheet.  Return to igure 8.
F
Figure 21
Description:
Ballistic Resistant Glazing Selection Procedure
5.5.1
Required Information.  The following information is
required for a ballistic resistant glazing selection:
a) Ballistic Tactic Design Basis Threat (medium, high,
or very high). This information is determined using
Appendix D and is recorded on the Glazing System
Design Criteria Summary worksheet.
b) Worksheets (See Appendix B):
1)  Cross-Section Selection (CSS)
2)  Frame Selection (FS)
3)  Wall Selection (WS)