Custom Search
|
|
|
||
MIL-HDBK-1013/12
resist low threat severity
laminated strengthened
level.
glass in standard frame.
2. Minimize number of windows.
2. Minimize number of windows.
1. Provide glazing system to
1. Provide 1/4-inch (6-mm)
Medium,
resist medium threat
laminated strengthened
High, and
severity level.
glass in standard frame.
Very High
2. Minimize number of windows.
2. Minimize number of windows.
7.3.1
Required Information. The following information is
required for a forced entry analysis for selection application:
a) Forced Entry Tactic Design Basis Threat (medium,
high, or very high). This information is determined
using Appendix D and is recorded on the Glazing
System Design Criteria Summary worksheet.
b) Level of Protection (low or medium). This
information is determined using Figure D-20 and is
recorded on the Glazing System Design Criteria
Summary worksheet.
c) Worksheets (see Appendix B):
1) Cross-Section Selection (CSS)
2) Frame Selection (FS)
3) Anchorage Selection (AS)
4) Wall Selection (WS)
66
|
||