Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 


MIL-HDBK-1013/12
Table D-23
Accessibility of Bulk Storage of AA&E
Type of Storage
Likelihood Rating
Factor
2
AA&E is stored in standard magazines
within a fenced or walled area with
security lighting and is monitored by IDS
installed to facilitate delay after
detection or is under constant
surveillance.
4
AA&E is stored in standard magazines
within a fenced or walled area and is
monitored by IDS installed to facilitate
delay after detection or is under
constant surveillance.
AA&E is stored in standard magazines
6
within a fenced or walled area with
security lighting.  Roving patrols check
the area hourly.
Table D-24
Accessibility of Unit Level Storage of AA&E
Type of Storage
Likelihood Rating
Factor
AA&E is stored in a standard magazine or
2
arms room and is monitored by IDS
installed to facilitate delay after
detection or is under constant
surveillance.  The facility or magazine
is within a fenced or walled area with
security lighting or building exterior
lighting.
AA&E is stored in a standard magazine
4
within a fenced or walled area or in a
standard arms room and is monitored by
IDS installed to facilitate delay after
detection or is under constant
surveillance.
AA&E is stored in a standard magazine
6
within a fenced or walled area with
security lighting or in a standard arms
room in a facility with exterior
lighting.  The area is checked hourly by
a roving patrol.
AA&E is not stored in a standard magazine
8
or arms room.  It is stored within a
fenced or walled area with perimeter
lighting or in a facility with exterior
lighting.  The area is checked hourly by
a roving patrol.