Custom Search
|
|
|
||
MIL-HDBK-1013/1A
+)))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))),
*
*
*
*
(b) Restricted Areas. Areas within facilities
*
*
or the installation which require restricted access.
*
*
(c) Access Controls. Who or what is to be
*
*
controlled, to what degree and where and when the
*
*
controls apply, e.g., personnel identity and weapons
*
*
checks, vehicle checks, and checks of packages.
*
*
(d) Functional Requirements. How the user will
*
*
operate the facility including relationships between
*
*
organizations or components of organizations, work
*
*
schedules, types of operations to be performed, and
*
*
special requirements for facility layout or
*
*
construction.
*
*
(5) Facility and Site Constraints. Examine the
*
*
installation's Master Plan, existing facilities, and
*
*
the proposed project (if using standard definitive
*
*
designs) to identify requirements related to site or
*
*
facility layout or construction. Potential constraints
*
*
include:
*
*
(a) Occupancy Requirements. Identify space
*
*
requirements, ventilation and window ratios, and other
*
*
occupancy-related design constraints.
*
*
(b) Life Safety Considerations. Egress
*
*
requirements related to fire safety constraints,
*
*
protective measures, and building layout.
*
*
(c) Occupational Safety and Health Concerns.
*
*
Whether personnel safety measures conflict with or
*
*
inhibit security measures.
*
*
(d) Barrier-Free Accessibility. Public
*
*
facilities and facilities which shelter military
*
*
dependents or civilians must conform to the Uniform
*
*
Federal Accessibility Standards which may constrain
*
*
security-related design.
*
*
(e) Parking Lots and Roads. Requirements for
*
*
parking lots and roads which could impact security,
*
*
e.g., how close to the protected building vehicles may
*
*
be allowed to approach or park with and without entry
*
*
control.
*
*
(f) Fences and Lighting. Identify restrictions
*
*
for installation of fences or security lighting.
*
*
.))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))-
Figure 3
Checklist of Other Design Constraints and Requirements (Continued)
20
|
||