c) 8-inch (200-mm) Reinforced Concrete Block 
d) 8-inch (200-mm) Reinforced Concrete 
Table 1 presents minimum wall construction requirements for the 
four wall systems covered.  Refer to MIL-HDBK-1013/1A for 
additional design guidance on wall systems. 
2.5.1 
Wood Frame.  This wall system is the minimum wall 
construction required to provide 1 minute of protection against 
forced entry attack with a low level tool mix.  This wall 
construction is not recommended for protection against ballistic 
or bomb attacks. 
2.5.2 
Unreinforced Brick.  This is a minimum wall 
construction requirement for storage structures for Arms, 
Ammunition, and Explosives (AA&E) risk categories I through IV. 
The wall construction is listed in Department of Defense (DOD) 
5100.76-M, Physical Security of Conventional Arms, Ammunition, 
and Explosives.  This wall system can be used for protection 
against low severity level forced entry attacks. 
2.5.3 
8-inch Reinforced Concrete Block.  This is a minimum 
wall construction requirement for storage structures for AA&E 
risk category I through IV.  The wall construction is listed in 
DOD 5100.76-M. 
2.5.4 
8-inch Reinforced Concrete.  This is a minimum wall 
construction requirement for storage structures for AA&E risk 
category I through IV.  The wall construction is listed in DOD 
5100.76-M. 