MIL-HDBK-1013/12
c) 8-inch (200-mm) Reinforced Concrete Block
d) 8-inch (200-mm) Reinforced Concrete
Table 1 presents minimum wall construction requirements for the
four wall systems covered.  Refer to MIL-HDBK-1013/1A for
additional design guidance on wall systems.
2.5.1
Wood Frame.  This wall system is the minimum wall
construction required to provide 1 minute of protection against
forced entry attack with a low level tool mix.  This wall
construction is not recommended for protection against ballistic
or bomb attacks.
2.5.2
Unreinforced Brick.  This is a minimum wall
construction requirement for storage structures for Arms,
Ammunition, and Explosives (AA&E) risk categories I through IV.
The wall construction is listed in Department of Defense (DOD)
5100.76-M, Physical Security of Conventional Arms, Ammunition,
and Explosives.  This wall system can be used for protection
against low severity level forced entry attacks.
2.5.3
8-inch Reinforced Concrete Block.  This is a minimum
wall construction requirement for storage structures for AA&E
risk category I through IV.  The wall construction is listed in
DOD 5100.76-M.
2.5.4
8-inch Reinforced Concrete.  This is a minimum wall
construction requirement for storage structures for AA&E risk
category I through IV.  The wall construction is listed in DOD
5100.76-M.