Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Custom Search
 
  
 


MIL-HDBK-1013/12
Table E-11
Actions for Example Number 4, Continued
Action
Action
Procedure
Figure
Structure
Number
Number
Number
55
Enter glazing dimensions. Enter "22, 34".
Glazing Data Entry
Figure C-8
<1>
56
Enter number of stacked plates. Enter "1".
<2>
57
Enter bite. Press "Enter" key.
<3>
58
For plate:
<4>
59
Enter type of glazing material. Press the "A"
<5>
and "Enter" keys.
60
Is material glass? Yes.
<6>
61
Enter number of layers in plate. Enter "2".
<7>
62
Enter layer thickness codes. Enter "1,1".
<8>
63
Confirm thicknesses. Press "Enter" key.
<9>
64
Do Explosives Data Entry procedure.
Data Entry
Figure C-7
<2>
Explosives Data
Figure C-10
<1>
65
Select blast load model. Select "DOE\TIC-
Entry
11268 TNT Equivalencies" and press the
"Enter" key.
66
Enter window coordinates. Enter "0,60,5"
<2>
67
Enter charge shape. Press the "H" and
<3>
"Enter" keys.
68
Select explosive type. Enter "23" and press
<4>
the "Enter" key.
69
Enter TNT equivalent weight factor. Press
<5>
the "Enter" key.
70
Enter explosives weight. Press the "2" and
<6>
"Enter" keys.
71
Skip loading function display. Press the "Y"
<7>
and "Enter" keys.
72
Do Algorithm Data Entry procedure
Data Entry
Figure C-7
<3>
73
Enter critical damping percent. Press the
Algorithm Data
Figure C-12
<1>
"Enter" key.
Entry
74
Enter number of integration time steps. Press
<2>
the "Enter" key.
75
Enter probability of failure of glass. Press the
<3>
"Enter" key.
76
Choose resistance function. Select "Beason-
<4>
Vallabhan" and press the "Enter" key.
77
Start analysis. Press the "C" key.
<5>
78
Do Results Analysis procedure.
Safevue Selection
Figure C-13
<7>
Analysis
260