Up
Entry Control Facilities
Entry Control Facilities
Technical Guidance
Distribution
Distribution -Cont.
Entry Control Facilities
Table of Contents
Table of Contents -Cont.
List of Figures
Introduction
Purpose of Guidance
Existing Requirements and Guidance
Table 2-1 FPCON Descriptions (ref. DoD O-2000.12-H)
Existing Design Guidance
Entry Control Facility Classifications and Functions
ECF Functional Diagrams
ECF Organization / Structure
Access Control Zone
Typical Operations in Access Control Zone
Determining Response Time and Length of Response Zone
Safety Zone
Safety Zone -Cont.
Entry Control Facility Design Considerations
Access Control Zone Guidelines
Figure 4.1Access Control Zone Operated by Security Personnel
Figure 4.2 Access Control Zone Operated by Automated Equipment
Containment and Control of Vehicles
Vehicle Barriers
Vehicle Inspection Capability
Capability to Reject Unauthorized Vehicles
Channelization Islands
Transitions and Tapers
Traffic Considerations
Traffic Control
Markings
Pedestrian Considerations
Figure 4.5 Typical Locations for Provision of Future Power/Control Connections
Exterior Lighting
Table 4-2 Minimum Exterior Illuminances
Communications and Information Technology
Personnel Protection
Gatehouse
Auxiliary Guard Positions / Fighting Positions
Environmental Control
Visitor Control Center / Pass Office (FUTURE)
Entry Control Facility Design Philosophy
Design Scenario 4
Prototypical Entry Control Facility
Variations and Alterations to the Prototype
Truck Inspection Facility Design Considerations
Under Vehicle Lighting System
CCTV Under Vehicle Search Systems
Vehicle Inspection Technologies Und-Aware AG-300 UVSS, BG-200
Cargo and Vehicle Inspection Systems
Mobile Vehicle Inspection Systems (Imaging)
Figure 7.4 Example Exclusion Zones for Mobile Inspection Systems
Fixed / Portable Vehicle X-Ray Inspection Systems (Imaging)
Figure 7.5 VACIS II - Gamma Ray Imaging System
Image
Figure 7.8 VACIS II - Gamma Ray Imaging System Exclusion Zones
Figure 7.9 VACIS II - Gamma Ray Imaging System Exclusion Zones
Figure 7.10 Shaped Energy ISO Search X-Ray System Radiation Levels
Fixed / Portable Vehicle X-Ray Inspection Systems (Imaging) -Cont.
Layout
Figure 7.11 Truck Inspection Facility Incorporating Mobile Imaging Systems
Figure 7.12 Truck Inspection Facility Incorporating a Fixed Imaging System
Figure 7.13Truck Inspection Facility Incorporating a Portal Imaging System
Geometric Design of Roadways
Overhead Canopy
Electrical Power Requirements
Communications and Information Technology
References
Appendix 1 Prototype Design Drawings
Appendix 1 Prototype Design Drawings -Cont.
Appendix 1 Prototype Design Drawings -Cont.
Appendix 1 Prototype Design Drawings -Cont.
Appendix 1 Prototype Design Drawings -Cont.
Blank Page
Entry Control Facilities
Privacy Statement
-
Copyright Information.
-